House electrical wiring: sizes, earthing and safety
Common wire sizes, six rules for safe wiring and how to keep your house ready for solar and backup.
Wiring is hidden inside walls for decades, so it is worth doing right the first time. Most electrical fires and shocks in homes come from under-sized wires, overloaded circuits and missing earthing.
Wire sizes commonly used in Pakistan
| USE | COMMON SIZE |
|---|---|
| Lights and fans | 3/.029 |
| Ordinary sockets | 7/.029 |
| AC, geyser, heavy appliances | 7/.036 or larger, on its own circuit |
These are typical; the right size depends on the load and the length of the run, and should come from your electrical drawing.
Six rules for safe wiring
- Separate circuits: lights, sockets and each AC on their own breakers, so one fault does not trip the whole house.
- Breakers sized to the wire: a breaker must trip before the wire overheats.
- Earthing: a proper earth pit and an earth wire to every socket and metal fitting.
- Shock protection: a residual current device (RCD/ELCB) to cut power when current leaks to earth, especially for bathrooms and outdoor points.
- Wires in conduit, with joints only inside boxes, never buried in plaster.
- Plan the load: count ACs, geysers, the water motor and future solar before choosing the main cable and distribution board.
Ready for solar and backup
Even if you do not install solar now, leave space at the distribution board and a conduit route to the roof. Keep the circuits you want on backup (lights, fans, fridge, router) grouped together, so a UPS or solar inverter can feed them later.
Records to keep
Ask for an as-built electrical drawing and photos of the conduits before plaster. RENOBILD hands over a House File with photos of every hidden pipe and wire.
گھر کی وائرنگ: سائز، ارتھنگ اور حفاظت
عام طور پر لائٹ اور پنکھوں کے لیے 3/.029، ساکٹ کے لیے 7/.029 اور اے سی جیسی بھاری چیزوں کے لیے 7/.036 یا اس سے موٹی تار ہر ایک کے الگ سرکٹ پر استعمال ہوتی ہے۔ ہر سرکٹ پر مناسب بریکر، پکی ارتھنگ اور کرنٹ لیک ہونے پر بجلی کاٹنے والا آر سی ڈی لگوائیں۔ تاریں ہمیشہ پائپ کے اندر ہوں۔
Questions people ask
Which wire is used for AC in Pakistan?اے سی کے لیے کون سی تار لگتی ہے؟
Commonly 7/.036 or larger on its own circuit and breaker; the exact size depends on the AC load and the length of the run.
Is earthing necessary in a house?کیا گھر میں ارتھنگ ضروری ہے؟
Yes. A proper earth pit and earth wire to every socket and metal fitting protect against shocks and help breakers and RCDs work.
What is an RCD or ELCB?آر سی ڈی یا ای ایل سی بی کیا ہے؟
A device that cuts the power when current leaks to earth, for example through a person. It is especially important for bathrooms and outdoor points.
Send 3–4 photos or your plot size on WhatsApp
We reply with what it probably is and the next step. Across Pakistan; overseas clients by video call.